Installation and maintenance of solenoid valve

Miniature hydraulic valves is one of the valves used in the automatic control system, it gets the user’s consistent favor because of low price, simple operation, convenient and reliable(it can directly accept the PLC or DCS switch quantity control signal). We will simply explain what you need to pay attention to while the installation and the maintenance of ng3 valve below.
Installation notes:
1.First check if the miniature hydraulic valves is consistent with the selection parameters, such as power supply voltage, medium pressure, pressure, etc.. Especially the power, if wrong, it will burn out coil. Power supply voltage should meet the voltage range of voltage fluctuation range: AC +10%~-15%, DC +10%~-10%, usually the coil assembly is not open.
2.To flush the pipes before taking over, remove metal powder, seal material, rust and dirt in the pipe. Need to pay attention to the medium cleanliness, if the medium mixed with dirt and impurities that impede the normal work of the ng3 valve, the filter or strainer should be installed in the pipeline.
3.miniature hydraulic valves solenoid coil components should be installed vertically in the horizontal pipe. If you are subject to space constraints or other conditions have to installed it on the side, need to be put forward in order.Otherwise it may cause the solenoid valve does not work.
4.Manual shutoff valve should be added before and after the ng3 valve,and should be set to bypass, easy maintenance.
5.Hydraulic directional valve is generally oriented, cannot be reversed. Usually mark on the valve body with an arrow indicating the direction of the flow of the media, it should be installed in accordance with the direction of the arrow. But in the vacuum line or special circumstances can be reversed.
6.If the medium caused a water hammer effect, then you should use the miniature hydraulic valves with prevent water hammer effect function or take corresponding preventive measures.
7.Don’t let the ng3 valve is energized for a long time, it is easy to reduce the service life of the coil and even burn the coil.
8.The inlet side of the steam hydraulic directional valve shall be provided with a steam trap, which shall be inclined to take over.

没有评论: